Solar

TAURUS 60 Gas Turbine Generator Set

General Specifications

Taurus™ 60 Gas Turbine

Industrial, Single-Shaft Transducers* On-Crank/On-Line

12 Stage Axial Compressor NEMA Class F Insulation Portable Cleaning Tank*

Variable Inlet Guide Vanes and Stators Class F Temperature Rise Package Power

Pressure Ratio: 12.2:1 Class B Temperature Rise* 120VDC Battery/Charger System*

Inlet Airflow: 21.5 kg/sec (47.3 lb/sec) Continuous Duty Rating Voltages: Turbotronic On-Skid Gas Turbine and

Vertically Split Case 3300, 6600, 11 000 (50Hz) Generator Control System Features

Combustion Chamber, Annular-Type 4160, 6900, 12 470, 13 200, 13 800 (60Hz) Combination Generator Control Module

12 Conventional Fuel Injectors or Package with Load Share, Auto Synchronization,

12 Lean-Premixed, Dry Low Mechanical Construction Voltage Control

Emissions SoLoNOx Injectors Steel Base Frame with Drip Pans Standard Display with Discrete Event Log,

Single Torch Ignitor System 316L Stainless Steel Piping Strip Chart, Historical Trend,

Power Turbine Compression Type Tube Fittings Maintenance Screen

Vibration and Temperature Monitoring

3-Stage Reaction Start System English Display Text and Labels

Clockwise Rotation Direct Drive AC Motor with VFD Control Spanish, Portuguese, German, French

Bearings Package Electrical Certification or Simplified Chinese Display Text

3 Radial Journal: Tilt-Pad NEC, CSA Class 1, Group D, Div.2 and Labels*

1 Thrust, Active: Tilt-Pad Fuel System Auxiliary and Remote Display/Control

1 Thrust, Inactive: Fixed Tapered Land Natural Gas Terminals*

Coatings Diesel* Turbine Performance Map*

Compressor: Inorganic Aluminum Dual (Natural Gas and Diesel)* KW Import Control*

Turbine and Nozzle Blades: Precious Low BTU Gas* KVAR/Power Factor Control*

Metal Diffusion Aluminide Integrated Lube Oil System ControlNet Redundant Media, Ethernet

Vibration Transducer Type Turbine-Driven Lube Pump or Modbus RS232C/422/485 Supervisory

Proximity Probes, 2 per Radial Bearing/ AC Motor Driven Pre/Post Lube Pump Interface*

2 per Thrust Bearing, horizontal DC Motor Driven Backup Lube Pump Heat Recovery Application Interface*

and vertical Air to Oil Cooler Multi-Unit Applications: Load Shed Control,

Main Reduction Drive Water to Oil Cooler* Import/Export or kW/KVAR Control Panels*

Integral Lube Oil Tank InSight Platform Equipment Health

Epicyclic Type Lube Oil Tank Heater Management*

1500 or 1800 rpm (50 or 60 Hz) Lube Oil Filter Printer/Logger*

Vibration monitoring: Acceleration Duplex Lube Oil Filter* Electrical System Options

Transducer Oil Tank Vent Separator with Neutral Grounding Resistor or Transformer*

Generator Flame Arrestor Switchgear and Generator Protective Relay*

4 Pole, 3 Phase, 6 Wire, Wye Connected, Air Inlet and Exhaust Systems Motor Control Center with Automatic Synchronous with Permanent Magnet   Carbon Steel  Transfer Switch*

Generator Exciter Stainless Steel* Documentation

Available Construction Types: Barrier Type Filters Drawings

Open Drip-Proof Construction Self-Cleaning Filters Quality Control Data Book

CACA/TEAAC (Closed Air, Cooling Air/ Inlet and Exhaust Silencers Inspection and Test Plan Totally Enclosed, Air to Air Cooling)* Inlet Evaporative Cooler* Test Reports

CACW/TEWAC (Closed Air, Cooling Inlet Chiller Coils* O&M Manuals

Water/Totally Enclosed, Water to Air Enclosure Factory Testing of Turbine

Cooling)* Complete Package Factory Testing of Package Systems

Sleeve Bearings Driver Only* Non-Dynamic

Vibration Monitoring; Velocity Transducers Fire Detection and CO2 Suppression Dynamic

Vibration Monitoring; Displacement System

Turbine Compressor Cleaning Systems