General Specifications
Taurus™ 60 Gas Turbine
• Industrial, Single-Shaft Transducers* – On-Crank/On-Line
• 12 Stage Axial Compressor • NEMA Class F Insulation – Portable Cleaning Tank*
– Variable Inlet Guide Vanes and Stators • Class F Temperature Rise • Package Power
– Pressure Ratio: 12.2:1 • Class B Temperature Rise* – 120VDC Battery/Charger System*
– Inlet Airflow: 21.5 kg/sec (47.3 lb/sec) • Continuous Duty Rating Voltages: • Turbotronic™ On-Skid Gas Turbine and
– Vertically Split Case – 3300, 6600, 11 000 (50Hz) Generator Control System Features
• Combustion Chamber, Annular-Type – 4160, 6900, 12 470, 13 200, 13 800 (60Hz) – Combination Generator Control Module
– 12 Conventional Fuel Injectors or Package with Load Share, Auto Synchronization,
12 Lean-Premixed, Dry Low • Mechanical Construction Voltage Control
Emissions SoLoNOx™ Injectors – Steel Base Frame with Drip Pans – Standard Display with Discrete Event Log,
– Single Torch Ignitor System – 316L Stainless Steel Piping Strip Chart, Historical Trend,
• Power Turbine – Compression Type Tube Fittings Maintenance Screen
– Vibration and Temperature Monitoring
– 3-Stage Reaction • Start System – English Display Text and Labels
– Clockwise Rotation – Direct Drive AC Motor with VFD Control – Spanish, Portuguese, German, French
• Bearings • Package Electrical Certification or Simplified Chinese Display Text
– 3 Radial Journal: Tilt-Pad – NEC, CSA Class 1, Group D, Div.2 and Labels*
– 1 Thrust, Active: Tilt-Pad • Fuel System – Auxiliary and Remote Display/Control
– 1 Thrust, Inactive: Fixed Tapered Land – Natural Gas Terminals*
• Coatings – Diesel* – Turbine Performance Map*
– Compressor: Inorganic Aluminum – Dual (Natural Gas and Diesel)* – KW Import Control*
– Turbine and Nozzle Blades: Precious – Low BTU Gas* – KVAR/Power Factor Control*
Metal Diffusion Aluminide • Integrated Lube Oil System – ControlNet Redundant Media, Ethernet
• Vibration Transducer Type – Turbine-Driven Lube Pump or Modbus RS232C/422/485 Supervisory
– Proximity Probes, 2 per Radial Bearing/ – AC Motor Driven Pre/Post Lube Pump Interface*
2 per Thrust Bearing, horizontal – DC Motor Driven Backup Lube Pump – Heat Recovery Application Interface*
and vertical – Air to Oil Cooler – Multi-Unit Applications: Load Shed Control,
Main Reduction Drive – Water to Oil Cooler* Import/Export or kW/KVAR Control Panels*
– Integral Lube Oil Tank – InSight Platform™ Equipment Health
• Epicyclic Type – Lube Oil Tank Heater Management*
– 1500 or 1800 rpm (50 or 60 Hz) – Lube Oil Filter – Printer/Logger*
– Vibration monitoring: Acceleration – Duplex Lube Oil Filter* • Electrical System Options
Transducer – Oil Tank Vent Separator with – Neutral Grounding Resistor or Transformer*
Generator Flame Arrestor – Switchgear and Generator Protective Relay*
• 4 Pole, 3 Phase, 6 Wire, Wye Connected, • Air Inlet and Exhaust Systems – Motor Control Center with Automatic Synchronous with Permanent Magnet – Carbon Steel Transfer Switch*
Generator Exciter – Stainless Steel* • Documentation
• Available Construction Types: – Barrier Type Filters – Drawings
– Open Drip-Proof Construction – Self-Cleaning Filters – Quality Control Data Book
– CACA/TEAAC (Closed Air, Cooling Air/ – Inlet and Exhaust Silencers – Inspection and Test Plan Totally Enclosed, Air to Air Cooling)* – Inlet Evaporative Cooler* – Test Reports
– CACW/TEWAC (Closed Air, Cooling – Inlet Chiller Coils* – O&M Manuals
Water/Totally Enclosed, Water to Air • Enclosure • Factory Testing of Turbine
Cooling)* – Complete Package • Factory Testing of Package Systems
• Sleeve Bearings – Driver Only* – Non-Dynamic
• Vibration Monitoring; Velocity Transducers – Fire Detection and CO2 Suppression – Dynamic
• Vibration Monitoring; Displacement System
Turbine Compressor Cleaning Systems