HGTP is an experienced company that can provide customers with complete maintenance, repair and overhauls of OEM and Non-OEM steam turbines and also with spare parts manufactured using our own documentation or documentation that is a product of reverse engineering.
Diagnostics and adjustments of the control system as necessary
Complete functional check of the protection system of the turbine
Check of the linearity of control valves
Endoscope inspection where possible
Overall visual check of the turbogenerator
Diagnostic measuring during the operation
Maintenance which is impossible to execute on a running machine
Repair of imperfections which may have been found during operation
Decoupling for rotors alignment check
Bearings inspection – visual, PT and UT
Check of vibration monitoring, endoscope inspection
Adjustment of lube oil and the hydraulic control oil system
Diagnostic measuring on the generator
Opening the turbine casings
Check of radial and axial tolerances
Cleaning and repair of the turbine steam flow path
Cleaning and flushing of lubrication oil & hydraulic oil systems
Cleaning of the condenser & heaters
Re-setting of clearances and the mechanical items within the control system
Execution of maintenance tasks that take longer than one week
Check of the exciter and generator
During a General Inspection all the equipment and accessories should be opened to allow for an inspection of the internals, NDT inspection (where necessary) and large-scale diagnostic measurements
Machining
Welding
Straightening
Replacement of damaged parts
High-speed balancing